Test |
Conditions |
Reference |
Endurance |
500 matings |
IEC61300-2-2 |
Vibration |
Frequency: 10 to 55Hz, Amplitude: 0.75mm |
IEC61300-2-1 |
Cable retention |
100N (patch cable); |
IEC61300-2-4 |
Strength of coupling mechanism |
80N for 2 to 3mm cable |
IEC61300-2-6 |
Cable torsion |
15N for 2 to 3mm cable |
IEC61300-2-5 |
Fall |
10 drops, 1m drop height |
IEC61300-2-12 |
Static lateral load |
1N for 1h (patch cable); |
IEC61300-2-42 |
Cold |
-25°C, 96h duration |
IEC61300-2-17 |
Dry heat |
+70°C, 96h duration |
IEC61300-2-18 |
Change of temperature |
-25°C to +70°C, 12 cycles |
IEC61300-2-22 |
Humidity |
+40°C at 93%, 96h duration |
IEC61300-2-19 |