S1720-52GWR-PWR-4X 10G SFP+ Fiber Optic Switch

Short Description:


Product Detail

Memory (RAM) 512 MB
Flash 512 MB in total, 240 MB available for customers
Mean time between failures (MTBF) 38 years
Mean time to repair (MTTR) 2 hours
Availability > 0.99999
Service port surge protection Common mode: ±7 kV
Power supply surge protection ±6 kV in differential mode, ±6 kV in common mode
Dimensions (H x W x D) Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 314.8 mm (1.72 in. x 17.40 in. x 12.39 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 323.8 mm (1.72 in. x 17.40 in. x 12.75 in.)
Weight (including packaging) 5.6 kg (12.35 lb)
Stack ports Not supported
RTC Not supported
RPS Not supported
PoE Supported
Rated voltage range 100 V AC to 240 V AC, 50/60 Hz
Maximum voltage range 90 V AC to 264 V AC, 47 Hz to 63 Hz
Maximum power consumption (100% throughput, full speed of fans) Without PoE: 63.5 W 100% PoE loads: 464.3 W (system power consumption: 94.7 W, PoE: 369.6 W)
Typical power consumption (30% of traffic load) Tested according to ATIS standard EEE enabled No PoE power consumption 42.2 W
Operating temperature 0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Short-term operating temperature -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year. The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year. The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.
Storage temperature -40°C to +70°C (-40°F to +158°F)
Noise under normal temperature (27°C, sound power) < 48.3 dB(A)
Relative humidity 5% to 95%, noncondensing
Operating altitude 0-5000 m (0-16404 ft.)