S5735S-L-M Series S5735S-L24P4S-MA 24 ports POE Switch
Short Description:
Memory (RAM) | 1 GB |
Flash | 512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) | 76.1 years |
Mean time to repair (MTTR) | 2 hours |
Availability | > 0.99999 |
Service port surge protection | Common mode: ±7 kV |
Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Weight (with packaging) | 4.31 kg (9. lb) |
Stack ports | Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions) |
RTC | Not supported |
RPS | Not supported |
PoE | Supported |
Rated voltage range | AC input: 100 V AC to 240 V AC, 50/60 Hz High-Voltage DC input: 240 V DC |
Maximum voltage range | AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz High-Voltage DC input: 190 V DC to 290 V DC |
Maximum power consumption (100% throughput, full speed of fans) | Not providing the PoE function: 53 W 100% PoE loads: 451 W (PoE: 380 W) |
Typical power consumption (30% of traffic load) Tested according to ATIS standard EEE enabled No PoE power consumption | 39 W |
Operating temperature | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Short-term operating temperature | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year. The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year. The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) | < 57.7 dB(A) |
Relative humidity | 5% to 95%, noncondensing |
Operating altitude | 0-5000 m (0-16404 ft.) |