Memory (RAM)
|
2 GB
|
Flash
|
512 MB in total. To view the available flash memory size, run the display version command.
|
Mean time between failures (MTBF)
|
69.53 years
|
Mean time to repair (MTTR) |
2
|
Availability
|
> 0.99999
|
Service port surge protection
|
NA
|
Power supply surge protection
|
Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode
Using DC power modules: ±1 kV in differential mode, ±2 kV in common mode
|
Dimensions (W x D x H)
|
442.0 mm x 220.0 mm x 44.4 mm (17.4 in. x 8.7 in. x 1.74 in.)
|
Weight (including packaging materials)
|
5.4 kg (11.91 lb) |
Stack ports
|
Any 10GE SFP+ ports (a maximum of 16 physical ports)
Any 40GE QSFP+ ports (a maximum of 2 physical ports)
|
RTC
|
Supported
|
RPS
|
Not supported
|
PoE
|
Not supported
|
Rated voltage range
|
100 V AC to 240 V AC, 50/60 Hz
-48 V DC to -60 V DC
|
Maximum voltage range
|
90 V AC to 264 V AC, 47 Hz to 63 Hz
-36 V DC to -72 V DC
|
Maximum power consumption (100% throughput, full speed of fans)
|
143.4 W
|
Typical power consumption (30% of traffic load, tested according to ATIS standard)
|
108.59 W
|
Operating temperature
|
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
|
Storage temperature
|
-40°C to +70°C (-40°F to +158°F)
|
Noise under normal temperature (27°C, sound power)
|
< 67.1 dB(A)
|
Relative humidity
|
5% to 95%, noncondensing
|
Operating altitude
|
AC power modules configured: 0-5000 m (0-16404 ft.)
DC power modules configured: 0-2000 m (0-6562 ft.)
|
Certification
|
EMC certification
Safety certification
Manufacturing certification
|
Part number
|
02350MTR |